Dell Storage SC5020配置SNMP
硬件--SC5020--编辑设置
SNMP版本选择v1/v2c,团体名为public,创建一个SNMP陷阱,陷阱目标为SNMP服务器地址,字符串public
运行SNMP
下载https://www.paessler.com/tools/snmptester
Device IP选择SC5020地址,版本V2c,团体名public,选择Scan interface,Start测试可以获取接口信息
下载模板 https://share.zabbix.com/storage-devices/dell/compellent-sc 并解压出来
管理--一般--值映射,添加
scItemStatus 1 => Up 2 => Down 3 => Degraded scProductIDGlobalStatus 1 => Other 2 => Unknown 3 => Ok 4 => Noncritical 5 => Critical 6 => Nonrecoverable scServerCnctvy 1 => Up 2 => Down 3 => Partial scScStatus 1 => Online 2 => Offline 3 => Unknown scDiskHealthy 1 => Healthy 2 => Not Healthy 3 => Unknown scDiskType 1 => FibreChannel 2 => iSCSI 3 => FibreChannelOverEthernet 4 => SAS 5 => Unknown scHostStatus 0 => Up 2 => Unreachable SNMP_interface_status 1 => Up 2 => Down 3 => Testing 4 => Unknown 5 => Dormant 6 => NotPresent 7 => LowerLayerDown
将echo.something传入zabbix服务器的/etc/zabbix/zabbix_agentd.d目录
cd /etc/zabbix/zabbix_agentd.d chmod a+x echo.something
配置--模板--导入模板文件
SNMP接口,建议不要勾选使用大量请求
配置--主机--选中SC5050主机--导入模板
完成