2019-06-28_090214.png

硬件--SC5020--编辑设置


2019-06-28_104637.png

SNMP版本选择v1/v2c,团体名为public,创建一个SNMP陷阱,陷阱目标为SNMP服务器地址,字符串public


2019-06-28_104648.png

运行SNMP


下载https://www.paessler.com/tools/snmptester

2019-06-28_105233.png

Device IP选择SC5020地址,版本V2c,团体名public,选择Scan  interface,Start测试可以获取接口信息


下载模板 https://share.zabbix.com/storage-devices/dell/compellent-sc 并解压出来

2019-07-11_140425.png

管理--一般--值映射,添加

scItemStatus
1 => Up
2 => Down
3 => Degraded

scProductIDGlobalStatus
1 => Other
2 => Unknown
3 => Ok
4 => Noncritical
5 => Critical
6 => Nonrecoverable

scServerCnctvy
1 => Up
2 => Down
3 => Partial

scScStatus
1 => Online
2 => Offline
3 => Unknown

scDiskHealthy
1 => Healthy
2 => Not Healthy
3 => Unknown

scDiskType
1 => FibreChannel
2 => iSCSI
3 => FibreChannelOverEthernet
4 => SAS
5 => Unknown

scHostStatus
0 => Up
2 => Unreachable

SNMP_interface_status
1 => Up
2 => Down
3 => Testing
4 => Unknown
5 => Dormant
6 => NotPresent
7 => LowerLayerDown


将echo.something传入zabbix服务器的/etc/zabbix/zabbix_agentd.d目录

cd /etc/zabbix/zabbix_agentd.d
chmod a+x echo.something

2019-07-11_141136.png


2019-07-11_140134.png

配置--模板--导入模板文件


2019-07-11_142623.png

SNMP接口,建议不要勾选使用大量请求


2019-07-11_141240.png

配置--主机--选中SC5050主机--导入模板


201907111562829798752688.png

完成


更新日期: 2019年06月28日
文章标签: Dell
文章链接: https://www.vos.cn/storage/321.html  